Unit Delay With Preview Enabled (Obsolete)
Output signal and signal delayed by one sample period, if external enable signal is on
Compatibility
Note
The Unit Delay With Preview Enabled block is not recommended. This block was removed from the Discrete library in R2016b. In new models, use the Delay block (with parameters set appropriately). Existing models that contain the Unit Delay With Preview Enabled block continue to work for backward compatibility.
Library
Additional Math & Discrete / Additional Discrete (until R2016b)
Description
The Unit Delay With Preview Enabled block supports calculations that have feedback and depend on the current input.
The block has two input ports: one for the input signal u
and one
for the external enable signal E
.
When the enable signal E
is on, the first port outputs the signal
and the second port outputs the signal delayed by one sample period. When the enable
signal E
is off, the block is disabled, and the state and output
values do not change, except during resets.
The enable signal is on when E
is not 0, and off when
E
is 0. This enable action is vectorized and supports scalar
expansion.
Having two outputs is useful for implementing recursive calculations where the result includes the most recent inputs. The second output can feed back into calculations of the block's inputs without causing an algebraic loop. Meanwhile, the first output shows the most up-to-date calculations.
You specify the block output for the first sampling period with the value of the Initial condition parameter.
You specify the time between samples with the Sample time
parameter. A setting of -1
means that the block inherits the
Sample time.
Data Type Support
The Unit Delay With Preview Enabled block accepts signals of the following data types:
Floating point
Built-in integer
Fixed point
Boolean
Enumerated
The outputs have the same data type as the input u
. For enumerated
signals, the Initial condition must be of the same enumerated type
as the input u
.
For more information, see Data Types Supported by Simulink in the Simulink® documentation.
Parameters
- Initial condition
Specify the initial output of the simulation.
- Sample time
Specify the time interval between samples. To inherit the sample time, set this parameter to
-1
. See Specify Sample Time in the online documentation for more information.
Characteristics
Direct Feedthrough | Yes, to first output port No, to second output port |
Sample Time | Specified in the Sample time parameter |
Scalar Expansion | Yes |
Zero-Crossing Detection | No |
Data Types | Double | Single | Boolean | Base Integer | Fixed-Point | Enumerated |
Sample Time | Specified in the Sample time parameter |
Direct Feedthrough | Yes, to first output port No, to second output port |
Multidimensional Signals | No |
Variable-Size Signals | No |
Zero-Crossing Detection | No |
Code Generation | Yes |
See Also
Unit Delay, Unit Delay Enabled (Obsolete), Unit Delay Enabled External IC (Obsolete), Unit Delay Enabled Resettable (Obsolete), Unit Delay Enabled Resettable External IC (Obsolete), Unit Delay External IC (Obsolete), Unit Delay Resettable (Obsolete), Unit Delay Resettable External IC (Obsolete), Unit Delay With Preview Enabled Resettable (Obsolete), Unit Delay With Preview Enabled Resettable External RV (Obsolete), Unit Delay With Preview Resettable (Obsolete), Unit Delay With Preview Resettable External RV (Obsolete)
Version History
Introduced before R2006a