Repair bus selections
Diagnostic action to take when upstream bus hierarchy changes break selections
Model Configuration Pane: Diagnostics / Connectivity
Description
The Repair bus selections configuration parameter determines the diagnostic action to take when changes to the upstream bus hierarchy break selections for Bus Selector and Bus Assignment blocks. By default, the software repairs the selections.
Settings
Warn and
repair
(default) | Error without repair
Warn and repair
The software displays a warning and updates the Bus Selector and Bus Assignment block parameter values to reflect upstream bus hierarchy changes.
Error without repair
The software displays an error and terminates the simulation. The error message indicates the block parameter values that you must update for the Bus Selector and Bus Assignment blocks to reflect upstream bus hierarchy changes.
Recommended Settings
Application | Setting |
---|---|
Debugging | No impact |
Traceability | No impact |
Efficiency | No impact |
Safety precaution | Warn and repair |
Programmatic Use
Parameter:
BusNameAdapt |
Values: 'WarnAndRepair' | 'ErrorWithoutRepair' |
Default: 'WarnAndRepair' |
Version History
Introduced in R2010a