Phase Coded Waveform
Phase-coded pulse waveform
Libraries:
Phased Array System Toolbox /
Waveforms
Description
The Phase-Coded Waveform block generates samples of a phase-coded pulse waveform with specified chip width, pulse repetition frequency (PRF), and phase code. The block outputs an integer number of pulses or samples.
Ports
Input
PRFIdx — PRF Index
positive integer
Index to select the pulse repetition frequency (PRF), specified as a positive integer. The index selects the PRF from the predefined vector of values specified by the Pulse repetition frequency (Hz) parameter.
Example:
4
Dependencies
To enable this port, select Enable PRF selection input.
Data Types: double
FreqOffset — Frequency offset
scalar
Frequency offset in Hz, specified as a scalar.
Example:
2e3
Dependencies
To enable this port, set Source of Frequency Offset to
Input port
.
Data Types: double
Output
Y — Pulse waveform
complex-valued vector
Pulse waveform samples, returned as a complex-valued vector.
Data Types: double
PRF — Pulse repetition frequency
positive scalar
Pulse repetition frequency of current pulse, returned as a positive scalar.
Dependencies
To enable this port, set the Output signal
format parameter to Pulses
and then select the Enable PRF output
parameter.
Data Types: double
Coeff — Matched filter coefficients
vector
Matched filter coefficients, returned as a vector.
Dependencies
To enable this port, select Enable Matched Filter Coefficients Output.
Data Types: double
Complex Number Support: Yes
Parameters
Sample rate (Hz) — Sample rate of the output waveform
1e6
(default) | positive scalar
Sample rate of the output waveform, specified as a positive scalar. Set the ratio of the Sample rate (Hz) parameter to the Pulse repetition frequency (Hz) parameter to an integer.
The ratio of Sample rate (Hz) to each element in the Pulse repetition frequency (Hz) vector must be an integer. This restriction is equivalent to requiring that the pulse repetition interval is an integral multiple of the sample interval.
The product of Sample rate (Hz) and Chip width (s) must be an integer. This restriction is equivalent to requiring that the chip width is an integer multiple of the sample interval.
Units are in Hz.
Example: 5e3
Phase code — Code type used for phase modulation
Frank
(default)
Code type used for phase modulation, specified as one of
Barker
Frank
P1
P2
P3
P4
Px
Zadoff-Chu
Maximum Length Sequence
Quadratic Residue Sequence
Custom
Example: P2
Custom phase code — Custom phase code
[1,-1]
(default) | M-length vector of complex values
Custom phase code, specified as a length-M vector of complex values. Each element in the specified vector corresponds to a single chip.
Example: [j,2/3,-j]
Dependencies
To enable this parameter, set the Code
parameter to 'Custom'
.
Data Types: double
Complex Number Support: Yes
Chip width (s) — Chip time duration
1e-5
(default) | positive scalar
Duration of every chip in a phase-coded waveform, specified as a positive scalar. The value of this parameter must satisfy these constraints:
The product of Chip width (s), Number of chips, and Pulse repetition frequency (Hz) must be less than or equal to one. This restriction is equivalent to requiring that the pulse length is less than the pulse repetition interval.
The product of Sample rate (Hz) and Chip width (s) must be an integer. This restriction is equivalent to requiring that the chip width is an integer multiple of the sample interval.
Units are in seconds.
Example: 2e-4
Number of chips — Number of chips in waveform
4
(default) | positive integer
Number of chips in a phase-coded waveform, specified as a positive integer. The product of the Chip width (s), Number of chips, and Pulse repetition frequency (Hz) parameters must be less than or equal to one. This restriction is equivalent to requiring that the chip width is an integer multiple of the sample interval.
The table shows additional constraints on the number of chips for different code types.
If the Phase code parameter is... | Then the Number of chips parameter must be... |
---|---|
Frank , P1 , or
Px | A perfect square |
P2 | An even number that is a perfect square |
Barker | 2, 3, 4, 5, 7, 11, or 13 |
'Maximum Length Sequence' | 7, 15, 31, 63, 127, 255, 511, 1023, 2047,
4095, and 8191 |
'Quadratic Residue
Sequence' | A prime number of the form
4 n-1 ,
where n is an integer |
Example: 9
Dependencies
To enable this parameter, set the Code
parameter to anything other than 'Custom'
.
Zadoff-Chu sequence index — Sequence index for Zadoff-Chu code type
1
(default) | positive integer
Sequence index for Zadoff-Chu code type, specified as a positive integer. The values of the Zadoff-Chu sequence index and the Number of chips parameters must be relatively prime.
Example: 2
Dependencies
To enable this parameter, set Phase Code to
Zadoff-Chu
.
Pulse repetition frequency (Hz) — Pulse repetition frequency
1e4
(default) | positive scalar
Pulse repetition frequency, PRF, specified as a scalar or a row vector. Units are in Hz. The pulse repetition interval, PRI, is the inverse of the pulse repetition frequency, PRF. The value of Pulse repetition frequency (Hz) must satisfy these constraints:
The product of Pulse width and Pulse repetition frequency (Hz) must be less than or equal to one. This condition expresses the requirement that the pulse width is less than one pulse repetition interval. For the phase-coded waveform, the pulse width is the product of the chip width and number of chips.
The ratio of sample rate to any element of Pulse repetition frequency must be an integer. This condition expresses the requirement that the number of samples in one pulse repetition interval is an integer.
You can select the value of PRF by using block parameter settings alone or
in conjunction with the input port, PRFIdx
.
When the Enable PRF selection input parameter is not selected, set the PRF using block parameters.
To implement a constant PRF, specify Pulse repetition frequency (Hz) as a positive scalar.
To implement a staggered PRF, specify Pulse repetition frequency (Hz) as a row vector with positive values. After the waveform reaches the last element of the vector, the process continues cyclically with the first element of the vector. When PRF is staggered, the time between successive output pulses cycles through the successive values of the PRF vector.
When the Enable PRF selection input parameter is selected, you can implement a selectable PRF by specifying Pulse repetition frequency (Hz) as a row vector with positive real-valued entries. But this time, when you execute the block, select a PRF by passing an index into the PRF vector into the
PRFIdx
port.
In all cases, the number of output samples is fixed when you set the
Output signal format to Samples
. When you
use a varying PRF and set Output signal format to
Pulses
, the number of output samples can vary.
Programmatic Use
Block Parameter:PRF |
Type:double |
Values:positive scalar |
Default:1e6 |
Enable PRF selection input — Select predefined PRF
off (default) | on
Select this parameter to enable the PRFIdx
port.
When enabled, pass in an index into a vector of predefined PRFs. Set predefined PRFs using the Pulse repetition frequency (Hz) parameter.
When not enabled, the block cycles through the vector of PRFs specified by the Pulse repetition frequency (Hz) parameter. If Pulse repetition frequency (Hz) is a scalar, the PRF is constant.
Programmatic Use
Block
Parameter:PRFSelectionInputPort |
Type:logical |
Values:positive scalar |
Default:off |
Source of Frequency Offset — Source of frequency offset
Property
(default) | Input port
Source of frequency offset, specified as Property
or
Input port
.
When set to
Property
, the offset is determined by the value of the Frequency Offset parameter.When set to
Input port
, the offset is determined by the value of the FreqOffset port.
Programmatic Use
Block
Parameter:FrequencyOffsetSource |
Type:enum |
Values:Property ,
Input Port
|
Default:Property |
Frequency Offset (Hz) — Frequency offset
0
(default) | scalar
Frequency offset, specified as a scalar. Units are in Hz.
Example: 2e3
Dependencies
To enable this parameter set the Source of Frequency Offset
parameter to Input port
.
Programmatic Use
Block
Parameter:FrequencyOffset |
Type:double |
Values:scalar
|
Default:0 |
Source of simulation sample time — Source of simulation sample time
Derive from waveform parameters
(default) | Inherit from Simulink engine
Source of simulation sample time, specified as Derive from waveform
parameters
or Inherit from Simulink engine
.
When set to Derive from waveform parameters
, the block runs
at a variable rate determined by the PRF of the selected waveform. The elapsed time is
variable. When set to Inherit from Simulink engine
, the
block runs at a fixed rate so the elapsed time is a constant.
Dependencies
To enable this parameter, select the Enable PRF selection input parameter.
Programmatic Use
Block
Parameter:SimulationTimeSource |
Type:enum |
Values:Derive from waveform
parameters , Inherit from Simulink
engine |
Default:Derive from waveform
parameters |
Output signal format — Format of the output signal
Pulses
(default) | Samples
The format of the output signal, specified as Pulses
or Samples
.
If you set this parameter to Samples
, the output of the block consists of multiple samples. The number of samples is the value of the Number of samples in output parameter.
If you set this parameter to Pulses
, the output of the block consists of multiple pulses. The number of pulses is the value of the Number of pulses in output parameter.
Programmatic Use
Block
Parameter:OutputFormat |
Type:enum |
Values:Pulses
Samples |
Default:Pulses |
Number of samples in output — Number of samples in output
100
(default) | positive integer
Number of samples in the block output, specified as a positive integer.
Example: 1000
Dependencies
To enable this parameter, set the Output signal format
parameter to Samples
.
Programmatic Use
Block
Parameter:NumSamples |
Type:double |
Values:positive
scalar
|
Default:100 |
Data Types: double
Number of pulses in output — Number of pulses in output
1
(default) | positive integer
Number of pulses in the block output, specified as a positive integer.
Example: 2
Dependencies
To enable this parameter, set the Output signal
format parameter to
Pulses
.
Programmatic Use
Block
Parameter:NumPulses |
Type:double |
Values:positive
scalar
|
Default:1 |
Data Types: double
Enable PRF Output — Enable output of PRF
off
(default) | on
Select this parameter to enable the PRF
output port.
Dependencies
To enable this parameter, set Output signal format to
Pulses
.
Programmatic Use
Block
Parameter:PRFOutputPort |
Type:enum |
Values:off
on |
Default:off |
Enable Matched Filter Coefficients Output — Enable output of matched filter coefficients
off
(default) | on
Select this parameter to enable the Coeff
output port.
Programmatic Use
Block
Parameter:CoefficientOutputPort |
Type:enum |
Values:off
on |
Default:off |
Simulate using — Block simulation method
Interpreted Execution
(default) | Code Generation
Block simulation, specified as Interpreted Execution
or
Code Generation
. If you want your block to use the
MATLAB® interpreter, choose Interpreted Execution
. If
you want your block to run as compiled code, choose Code
Generation
. Compiled code requires time to compile but usually runs
faster.
Interpreted execution is useful when you are developing and tuning a model. The block
runs the underlying System object™ in MATLAB. You can change and execute your model quickly. When you are satisfied
with your results, you can then run the block using Code
Generation
. Long simulations run faster with generated code than in
interpreted execution. You can run repeated executions without recompiling, but if you
change any block parameters, then the block automatically recompiles before
execution.
This table shows how the Simulate using parameter affects the overall simulation behavior.
When the Simulink® model is in Accelerator
mode, the block mode specified
using Simulate using overrides the simulation mode.
Acceleration Modes
Block Simulation | Simulation Behavior | ||
Normal | Accelerator | Rapid Accelerator | |
Interpreted Execution | The block executes using the MATLAB interpreter. | The block executes using the MATLAB interpreter. | Creates a standalone executable from the model. |
Code Generation | The block is compiled. | All blocks in the model are compiled. |
For more information, see Choosing a Simulation Mode (Simulink).
Programmatic Use
Block
Parameter:SimulateUsing |
Type:enum |
Values:Interpreted
Execution , Code Generation |
Default:Interpreted
Execution |
Version History
Introduced in R2014b
See Also
MATLAB Command
You clicked a link that corresponds to this MATLAB command:
Run the command by entering it in the MATLAB Command Window. Web browsers do not support MATLAB commands.
Select a Web Site
Choose a web site to get translated content where available and see local events and offers. Based on your location, we recommend that you select: .
You can also select a web site from the following list
How to Get Best Site Performance
Select the China site (in Chinese or English) for best site performance. Other MathWorks country sites are not optimized for visits from your location.
Americas
- América Latina (Español)
- Canada (English)
- United States (English)
Europe
- Belgium (English)
- Denmark (English)
- Deutschland (Deutsch)
- España (Español)
- Finland (English)
- France (Français)
- Ireland (English)
- Italia (Italiano)
- Luxembourg (English)
- Netherlands (English)
- Norway (English)
- Österreich (Deutsch)
- Portugal (English)
- Sweden (English)
- Switzerland
- United Kingdom (English)
Asia Pacific
- Australia (English)
- India (English)
- New Zealand (English)
- 中国
- 日本Japanese (日本語)
- 한국Korean (한국어)