Main Content

Baud rate

R2026b

Baud rate for the PIL or external mode simulation

Since R2022b

Model Configuration Pane: Hardware Implementation / Hardware board settings / Target hardware resources / Connectivity

Description

Select the baud rate for the processor-in-the-loop (PIL) or external mode simulation.

Dependencies

To enable this parameter, set Connectivity interface parameter to Serial (ASCLINX), or CAN (MCANY). The values of X and Y depend on the Device Series parameter value.

Settings

921600 (default)

The default value for universal measurement and calibration protocol (XCP)-based external mode simulation using serial communication is 921600 and for XCP-based external mode simulation using CAN communication is 1000kbps. The default value and the available options depend on the choice of Connectivity interface parameter value.

Tips

  • For XCP-based external mode simulation over CAN, this parameter value must match the value specified for the Baud rate parameter.

  • External mode communication over a serial connection at baud rates greater than 921600 might not operate reliably because of clock tolerance differences across Infineon AURIX hardware boards. If communication issues occur, use a lower baud such as 921600 or 500000. Alternatively, use a dedicated FTDI-based USB-to-UART adapter and configure the Connectivity interface, Tx Pin, and Rx Pin parameters.

Recommended Settings

ApplicationSetting
DebuggingNo impact
TraceabilityNo impact
EfficiencyNo impact
Safety precautionNo impact

Programmatic Use

No programmatic use is available.

Version History

Introduced in R2022b